Traitement municipal de l’eau potable : L’accès à l’eau potable est considéré comme un droit humain fondamental. Cependant, plus d’un sixième de la population mondiale, principalement dans les pays en développement, n’a pas un accès fiable à cette eau. Les clients se plaignent auprès des entreprises d’eau potable au sujet d’incidents comme le goût, l’odeur, la couleur, la boue, la basse pression et l’absence d’approvisionnement en eau. Au Royaume-Uni, on estime qu’un tiers de toutes les plaintes des clients concernant l’eau potable sont liées à la décoloration de l’eau (Cook et coll., 2005). Ces plaintes minent considérablement la confiance des clients dans les compagnies d’eau.
Iron and Manganese contamination of water have long been considered to only lead to aesthetic problems, in that they are secondary contaminants that have little or no adverse health effects. However, research conducted by Wasserman et al. (2006) indicated a relationship between increased Mn concentrations in drinking water and reduced intellectual functions of children. Increased levels of Iron and Manganese concentrations have been found to be the main cause of drinking water discolouration (Slaats, 2002). Furthermore, discoloured water could also lead to coloured stains on laundries and sinks, increased treatment costs, reduced treatment capacity and increased pumping costs. Water with high concentrations of Iron and Manganese has been found to give water an unpleasant metallic taste and vegetables cooked with it become dark and look unappetizing (Herman, 1996).
High Iron and Manganese levels can lead to non-compliance with drinking water regulations. The drinking water standard for most jurisdictions for iron is 0.3 milligrams per liter (mg/l), and the standard for manganese is 0.05 mg/l respectively. The quality of water changes as it travels from source to consumers in Water Distribution Networks (‘WDNs’). Although water companies generally set post-treatment targets of Fe and Mn to about 3% of their respective MCLs, low concentrations of Fe and Mn still enter the network and gradually accumulate on pipe walls within WDNs. Given the wrong conditions, such as high flows created by a water main burst or high diurnal consumption of drinking water, these accumulated particles may subsequently lead to water discolouration and end up in customers’ taps.
In order to begin the process of oxidation of the iron (and manganese) in solution DMI-65® is designed to operate in the presence of chlorine or other oxidants. In this process the oxidant removes electrons and is consumed in
the process. The operator needs to ensure that there is a 0.1 – 0.3 ppm free chlorine residual in the effluent water. Chlorine, fed as sodium hypochlorite or bleach (12.5% NaOCl), is the preferred oxidant since it is relatively inexpensive, readily available around the world and it is effective. It also performs the vast majority of any disinfectant process.
Unlike ion exchange resins where higher regenerant dosages will increase the ion exchange capacity, NaOCl residuals or concentrations higher than required to oxidize the Iron and Manganese do not increase the oxidative properties of the media. Additionally, since the media is often used to pretreat waters prior to an RO system a higher free chlorine residual would require more extensive post treatment to reduce the residual and protect the membranes from chlorine attack.
DMI-65® has been certified to the US Standard of NSF/ANSI 61 for Drinking Water System Components and for use in England and Wales Under Regulation 31(4)(a) of the water supply (Water Quality) regulations 2010 and has also been tested by many other water treatment authorities and laboratories.
George Municipal Water Works, Afrique du Sud, utilise plus de 550 tonnes métriques de DMI-65®. L’eau George est très colorée contenant des acides humiques et fulvic – la couleur brute de l’eau est approximative. 800 unités de couleur PtCo. Ce type d’eau est considéré comme l’un des plus difficiles à filtrer. L’enlèvement du fer est très efficace quel que soit le pH. Le fer résiduel le plus élevé trouvé était de 0,01 mg/L. L’enlèvement du manganèse est également très efficace. Le manganèse restant le plus élevé trouvé était 0.06 mg/l Mn est mieux enlevé au pH 8 plus élevé. L’avantage supplémentaire de l’enlèvement de l’aluminium, même au pH supérieur. La turbidité la plus élevée enregistrée était 0,06 NTU. Selon nos tests de laboratoire, la couleur la plus élevée était de 4 mg/l PtCo, mais la plupart du temps la couleur était inférieure à la couleur de l’eau distillée achetée dans une pharmacie de George. L’usine fonctionne depuis le début de janvier 2007 et continue d’avoir d’excellents résultats. George Municipal Water Works, utilise le même DMI-65® les supports de filtre pendant plus de 13 ans, sans défaillance ni diminution de la performance.
L’usine municipale de traitement de l’eau de Witbank, à Durban, en Afrique du Sud, se compose de 18 grands filtres à sable rapide utilisant 1 200 tonnes de filtres pour retirer le fer et le manganèse de la source locale d’eau souterraine. Des spécialistes locaux du traitement de l’eau et agent DMI-65®, Water Technologies Cape, ont démontré les avantages de performance et de coût de la mise à niveau du système en DMI-65®, par un essai pilote réussi en 2018. Les travaux de modernisation de l’usine ont commencé en 2019 et devraient être terminés d’ici la fin de 2020.